443
Appendix B: Event code tables
Power supply events (200 through 299)
Event Code: 200
Message:
Power supply ac voltage failure
Severity:
Major
Explanation:
Either the ac input to the indicated power supply has been lost, or the ac voltage has failed in the power supply
module. This event can only occur when dual power supplies are installed. The second supply automatically
assumes the full load to continue providing uninterrupted system power.
Action:
Ensure that the power cord is securely connected to the receptacles at both ends, and verify the ac source is live.
If the ac voltage does not recover (recovery is indicated by event 203), replace the faulty power supply. Perform
the data collection procedure for this unit using the EFC Manager, save the data file to the EFC Manager Zip
drive, and return the CD and the faulty power supply to IBM for analysis and repair.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EFC Server
Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log
Call-Home
Sense Info
Link Incident
✔
✔
✔
✔
✔
✔
Summary of Contents for SAN32M1
Page 1: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 2: ......
Page 3: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 12: ...SAN32M1 Fabric Switch Installation and Service Manual x...
Page 18: ...SAN32M1 Fabric Switch Installation and Service Manual xvi...
Page 20: ...SAN32M1 Fabric Switch Installation and Service Manual xviii...
Page 82: ...SAN32M1 Fabric Switch Installation and Service Manual 50...
Page 222: ...SAN32M1 Fabric Switch Installation and Service Manual 190...
Page 418: ...SAN32M1 Fabric Switch Installation and Service Manual 386...
Page 454: ...SAN32M1 Fabric Switch Installation and Service Manual 422...
Page 532: ...SAN32M1 Fabric Switch Installation and Service Manual 500...
Page 536: ...SAN32M1 Fabric Switch Installation and Service Manual 504...
Page 625: ......
Page 626: ...Printed in USA GC26 7665 01...