SAN32M1 Fabric Switch Installation and Service Manual
454
CTP card events (400 through 499)
Event Code: 400
Message:
Power-up diagnostics failure
Severity:
Major
Explanation:
The CTP power-on self test diagnostics detected a faulty FRU as indicated in the event data.
Action:
Replace the faulty FRU with a functional FRU. Perform the data collection procedure for the switch using the EFC
Manager, and return the CD and the faulty FRU to IBM for analysis and repair.
Event Data:
Byte 0: FRU code:
01 = LBA
02 = CTP
03 = SBAR
05 = Fan module
06 = Power supply
08-0F = Port module
Byte 1: Slot position
Byte 2: Device ID
Byte 3: Power-up error code (Internally defined) (stored in the faulty FRU EEPROM for analysis)
Bytes 4-7: Power-up data code (Internally defined) (stored in the faulty FRU EEPROM)
Distribution:
Switch
EFC Server
Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log
Call-Home
Sense Info
Link Incident
✔
✔
✔
✔
✔
✔
Summary of Contents for SAN32M1
Page 1: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 2: ......
Page 3: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Page 12: ...SAN32M1 Fabric Switch Installation and Service Manual x...
Page 18: ...SAN32M1 Fabric Switch Installation and Service Manual xvi...
Page 20: ...SAN32M1 Fabric Switch Installation and Service Manual xviii...
Page 82: ...SAN32M1 Fabric Switch Installation and Service Manual 50...
Page 222: ...SAN32M1 Fabric Switch Installation and Service Manual 190...
Page 418: ...SAN32M1 Fabric Switch Installation and Service Manual 386...
Page 454: ...SAN32M1 Fabric Switch Installation and Service Manual 422...
Page 532: ...SAN32M1 Fabric Switch Installation and Service Manual 500...
Page 536: ...SAN32M1 Fabric Switch Installation and Service Manual 504...
Page 625: ......
Page 626: ...Printed in USA GC26 7665 01...