Table 12. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
Action
8144
Informational system log entry only.
No corrective action is required.
8145
Informational system log entry only.
No corrective action is required.
8150
System firmware detected an error.
Collect a platform dump and then go to “Isolating
firmware problems” on page 222.
8151
System firmware detected an error.
Use the Integrated Virtual Manager (IVM) to increase the
Logical Memory Block (LMB) size, and to reduce the
number of virtual devices for the partition.
8152
No active system processor.
Verify that processor resources are assigned to the
partition.
8160
A problem occurred during the
migration of a partition.
Contact IBM support, as described in Appendix A,
“Getting help and technical assistance,” on page 285.
8161
A problem occurred during the
migration of a partition.
Contact IBM support, as described in Appendix A,
“Getting help and technical assistance,” on page 285.
A100
A partition ended abnormally; the
partition could not stay running and
shut itself down.
1.
Check the error logs and take the actions for the error
codes that are found.
2.
Go to “Isolating firmware problems” on page 222.
A101
A partition ended abnormally; the
partition could not stay running and
shut itself down.
1.
Check the error logs and take the actions for the error
codes that are found.
2.
Go to “Isolating firmware problems” on page 222.
A140
A lower priority partition lost a
usable processor to supply it to a
higher priority partition with a bad
processor.
Evaluate the entire LPAR configuration. Adjust partition
profiles with the new number of processors available in
the system.
B07B
Informational system log entry only.
No corrective action is required.
B215
A problem occurred after a partition
ended abnormally.
There was a communications
problem between this partition’s
service processor and the platform’s
service processor.
Restart the platform.
C1F0
An internal system firmware error
occurred during a partition
shutdown or a restart.
Go to “Isolating firmware problems” on page 222.
D150
A partition ended abnormally; there
was a communications problem
between this partition and the code
that handles resource allocation.
Check for server firmware updates; then, install the
updates if available.
E0AA
A problem occurred during the
power off of a partition.
Go to “Isolating firmware problems” on page 222.
F001
A problem occurred during the
startup of a partition. An operation
has timed out.
Look for other errors and resolve them.
38
JS12 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...