Table 12. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
Action
2054
A problem occurred during a
partition Main Storage Dump. A
mainstore dump IPL did not
complete due to a configuration
mismatch.
Go to “Isolating firmware problems” on page 222.
2058
A problem occurred during a
partition Main Storage Dump. A
mainstore dump startup did not
complete due to a copy error.
Go to “Isolating firmware problems” on page 222.
2210
Informational system log entry only.
No corrective action is required.
2220
Informational system log entry only.
No corrective action is required.
2250
During the startup of a partition, an
attempt to toggle the power state of
a slot has failed.
Check for server firmware updates; then, install the
updates if available.
2260
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 222.
2300
During the startup of a partition, an
attempt to toggle the power state of
a slot has failed.
Check for server firmware updates; then, install the
updates if available.
2310
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 222.
2320
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 222.
2425
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 222.
2426
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 222.
2475
During the startup of a partition, a
slot that was needed for the partition
was either empty or the device in
the slot has failed.
Check for server firmware updates; then, install the
updates if available.
2485
During the startup of a partition, the
partition firmware attempted an
operation that failed.
Go to “Isolating firmware problems” on page 222.
3000
Informational system log entry only.
No corrective action is required.
3081
During the startup of a partition, the
startup did not complete due to a
copy error.
Check for server firmware updates; then, install the
updates if available.
32
JS12 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...