Table 13. B700xxxx Licensed internal code SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
Description
Action
4401
System firmware failure. The system
firmware detected an internal problem.
Go to “Isolating firmware problems” on page
222.
4402
A system firmware error occurred while
attempting to allocate the memory
necessary to create a platform dump.
Go to “Isolating firmware problems” on page
222.
4705
System firmware failure. A problem
occurred when initializing, reading, or
using the system VPD. The Capacity on
Demand function is not available.
Restart the system.
4710
Informational system log entry only.
No corrective action is required.
4714
Informational system log entry only.
No corrective action is required.
4788
Informational system log entry only.
No corrective action is required.
5120
System firmware detected an error
If the system is not exhibiting problematic
behavior, you can ignore this error. Otherwise,
go to “Isolating firmware problems” on page
222.
5121
System firmware detected a
programming problem for which a
platform dump may have been initiated.
1.
Collect the event log information.
2.
Collect the platform dump information.
3.
Go to “Isolating firmware problems” on
page 222.
5122
An error occurred during a search for
the load source.
If the partition fails to startup, go to “Isolating
firmware problems” on page 222. Otherwise,
no corrective action is required.
5123
Informational system log entry only.
No corrective action is required.
5190
Operating system error. The server
firmware detected a problem in an
operating system.
Check for error codes in the partition that is
reporting the error and take the appropriate
actions for those error codes.
5191
System firmware detected a virtual I/O
configuration error.
1.
Use the Integrated Virtual Manager (IVM)
to verify or reconfigure the invalid virtual
I/O configuration.
2.
Check for server firmware updates; then,
install the updates if available.
5209
Informational system log entry only.
No corrective action is required.
5219
Informational system log entry only.
No corrective action is required.
5300
System firmware detected a failure
while partitioning resources. The
platform partitioning code encountered
an error.
Check the management-module event log for
error codes; then, take the actions associated
with those error codes.
5301
User intervention required. The system
detected a problem with the partition
configuration.
Use the Integrated Virtual Manager (IVM) to
reallocate the system resources.
Chapter 2. Diagnostics
43
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...