Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
2607-706
2607
Error Log Analysis indicates that a fatal hardware error has occurred for the Fibre
Channel adapter card.
This adapter was successfully taken off-line. It will remain off-line until reconfigured
or the system is rebooted. This adapter must be replaced and not brought back
on-line. Failure to adhere to this action could result in data being read or written
incorrectly or in the loss of data.
2624-xxx
2624
Generic reference for 4X PCI-E DDR InfiniBand Host Channel Adapter -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 187.
2624-101
2624
Configuration failure - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 187.
2624-102
2624
Queue pair create failure - system-board and chassis assembly. Go to “Performing
the checkout procedure” on page 187.
2624-103
2624
Loop back test failure - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 187.
2624-201
cable
network
Loop back test failure. Do the following steps one at a time, in order, and rerun the
test after each step:
1.
Reseat the cable.
2.
Replace the cable.
3.
Verify that the network is functional.
4.
Verify that the network switch is functional.
2624-301
cable
network
2624
Loop back test failure. Do the following steps one at a time, in order, and rerun the
test after each step:
1.
Reseat the cable.
2.
Replace the cable.
3.
Verify that the network is functional.
4.
Verify that the network switch is functional.
5.
Go to “Performing the checkout procedure” on page 187.
2624-701
2624
Error Log Analysis indicates that this adapter has failed due to an internal error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 187.
2624-702
2624
Error Log Analysis indicates that this adapter has failed due to a failure with the
uplink interface used to connect this device to the host processor - system-board and
chassis assembly. Go to “Performing the checkout procedure” on page 187.
2624-703
2624
Error Log Analysis indicates that this adapter has failed due to a memory error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 187.
2624-704
2624
Error Log Analysis indicates that this adapter has failed due to a unrecoverable
internal parity error - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 187.
2624-705
2624
Error Log Analysis indicates that this adapter has failed due to a internal error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 187.
2624-706
2624
Error Log Analysis indicates that this adapter has failed due to a memory error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 187.
2631–xxx
2631
Generic reference for IDE controller - system-board and chassis assembly. Go to
“Performing the checkout procedure” on page 187.
158
JS12 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...