Table 5. 1xxxyyyy SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
1xxxyyyy
Error Codes
Description
Action
8423
No processor VPD was found
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
84A0
No backplane VPD was found
1.
Go to “Checkout procedure” on page 186.
2.
Replace the system-board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on
page 274.
6xxxyyyy SRCs
The 6xxxyyyy system reference codes are virtual optical reference codes.
Look for the rightmost 4 characters (
yyyy
in 6xxx
yyyy
) in the error code; this is the
reference code. Find the reference code in Table 6.
Table 6. 6xxxyyyy SRCs
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
6xxxyyyy
Error Codes
Description
Action
632Byyyy codes are Network File System (NFS) virtual optical SRCs
632BCFC1
A virtual optical device cannot
access the file containing the
list of volumes.
On this partition and on the Network File System server, verify
that the proper file is specified and that the proper authority is
granted.
632BCFC2
A non-recoverable error was
detected while reading the list
of volumes.
Resolve any errors on the Network File System server.
632BCFC3
The data in the list of volumes
is not valid.
On the Network File System server, verify that the proper file is
specified, that all files are entered correctly, that there are no blank
lines, and that the character set used is valid.
632BCFC4
A virtual optical device cannot
access the file containing the
specified optical volume.
On the Network File System server, verify that the proper file is
specified in the list of volumes, and that the proper authority is
granted.
632BCFC5
A non-recoverable error was
detected while reading a
virtual optical volume.
Resolve any errors on the Network File System server.
632BCFC6
The file specified does not
contain data that can be
processed as a virtual optical
volume.
On the Network File System server, verify that all the files specified
in the list of optical volumes are correct.
22
JS12 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...