Table 25. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
FRU/action
A1D-19x
A non-critical error has been detected, a
service processor error accessing real
time clock/time-of-day clock.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A1D-20x
A non-critical error has been detected:
Service processor error accessing scan
controller/hardware.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A1D-21x
A non-critical error has been detected, a
service processor detected error with
time-of-day clock backup battery.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A1D-23x
A non-critical error has been detected:
Loss of heart beat from Service
Processor.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A1D-24x
A non-critical error has been detected, a
service processor detected a
surveillance time-out.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A1D-29x
A non-critical error has been detected, a
service process error accessing power
control network.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A1D-30x
A non-critical error has been detected:
Non-supported hardware.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
A1D-31x
A non-critical error has been detected:
Error detected while handling an
attention/interrupt from the system
hardware.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 88.
2.
If no entry is found, replace the system-board
and chassis assembly.
178
JS12 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...