Table 12. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
Action
5137
A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The main store dump startup
will continue.
Look for other errors and resolve them.
5145
A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The main store dump startup
will continue.
Look for other errors and resolve them.
5148
A problem occurred during the
startup of a partition. An error
occurred while doing a main storage
dump that would have caused
another main storage dump. The
startup will not continue.
Go to “Isolating firmware problems” on page 222.
5149
A problem occurred during the
startup of a partition while doing a
Firmware Assisted Dump that would
have caused another Firmware
Assisted Dump.
Check for server firmware updates; then, install the
updates if available.
514A
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
542A
A Firmware Assisted Dump did not
complete due to a read error.
Check for server firmware updates; then, install the
updates if available.
542B
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
543A
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
543B
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
543C
Informational system log entry only.
No corrective action is required.
543D
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
6006
During the startup of a partition, a
system firmware error occurred
when the partition memory was
being initialized; the startup will not
continue.
Go to “Isolating firmware problems” on page 222.
600A
A problem occurred during the
startup of a partition. The partition
could not reserve the memory
required for IPL.
Contact IBM support, as described in Appendix A,
“Getting help and technical assistance,” on page 285.
Chapter 2. Diagnostics
35
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...