Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Isolation
Procedure Code
Symptom
Action
FSPSP22
The system has
detected that a
processor chip is
missing from the
system configuration
because JTAG lines
are not working.
Replace the system board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on page 274.
FSPSP23
The system needs to
perform a service
processor dump.
1.
Save the service processor dump to storage by using the partition
dump pin control on the control panel.
2.
Once the dump is complete, attempt to re-IPL the system.
3.
Call IBM Support.
FSPSP24
The system is
running degraded.
Array bit steering
might be able to
correct this problem
without replacing
hardware.
1.
Power off the blade server, as described in “Turning off the blade
server” on page 8.
2.
Remove the blade server from the BladeCenter unit and reinsert the
blade server into the BladeCenter unit.
3.
Power on the blade server, as described in “Turning on the blade
server” on page 7.
4.
If the problem persists, replace the CRU that is called out after this
procedure.
FSPSP27
An attention line has
been detected as
having a problem.
Replace the CRU that is called out before this FSPSP27 call. If the CRU
does not correct the problem, call IBM Support.
FSPSP28
The resource ID (RID)
of the CRU could not
be found in the Vital
Product Data (VPD)
table.
1.
Find another callout that reads
″
FSPxxxx
″
where xxxx is a 4-digit hex
number that represents the resource ID. Record the resource ID and
the model of the system.
2.
Call IBM Support to find out what CRU the resource ID represents.
3.
Replace the CRU that the resource ID represents.
FSPSP29
The system has
detected that all I/O
bridges are missing
from the system
configuration.
Replace the system board and chassis assembly, as described in
“Replacing the Tier 2 system-board and chassis assembly” on page 274.
Chapter 2. Diagnostics
211
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...