Table 26. ssss-102 through ssss-640 SRNs (continued)
SRN
FFC
Description and action
ssss-122
ssss
A SCSI reservation conflict error.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 274.
ssss-124
ssss
A SCSI check condition error occurred.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 274.
ssss-126
ssss 252B
A software error was caused by a hardware failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 274.
ssss-128
252B ssss
software
The error log analysis indicates a hardware failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 274.
ssss-129
252B ssss
software
Error log analysis indicates a SCSI bus problem.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 274.
ssss-130
ssss
Error log analysis indicates a problem reported by the disk drive’s self-monitoring
function.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 274.
ssss-132
ssss
A disk drive hardware error occurred.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 88.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system board and chassis assembly, as described in “Replacing the
Tier 2 system-board and chassis assembly” on page 274.
182
JS12 Type 7998: Problem Determination and Service Guide
Summary of Contents for BladeCenter JS12
Page 1: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter JS12 Type 7998 Problem Determination and Service Guide...
Page 14: ...xii JS12 Type 7998 Problem Determination and Service Guide...
Page 248: ...234 JS12 Type 7998 Problem Determination and Service Guide...
Page 252: ...238 JS12 Type 7998 Problem Determination and Service Guide...
Page 290: ...276 JS12 Type 7998 Problem Determination and Service Guide...
Page 298: ...284 JS12 Type 7998 Problem Determination and Service Guide...
Page 302: ...288 JS12 Type 7998 Problem Determination and Service Guide...
Page 312: ...298 JS12 Type 7998 Problem Determination and Service Guide...
Page 317: ......
Page 318: ...Part Number 60Y1568 Printed in USA 1P P N 60Y1568...