Enterprise Server Model S80 (7017)
The S80 can be used with a T00 or T42 style I/O rack. See “Model T00 Rack” on page 31. The rack can
be ordered by feature code with your system.
System Rack
Dimensions
Height
1577 mm
62.0 in.
Width
567 mm
22.3 in.
Depth
1041 mm
40.9 in.
Weight
Minimum (Configuration dependant)
400 kg
880 lbs.
Electrical
Power source loading
2.129KVA
(maximum in kVA)
Voltage range (V ac)
200 to 240
Frequency (hertz)
50 - 60
Thermal output (Maximum)
6904 Btu/hr
Power requirements (Maximum)
2023 watts
Power factor
0.92 to 0.98
Inrush current
³
43 amps
Maximum altitude
2135 m (7000 ft.)
Temperature Requirements
4,5
Operating
10 to 37.8°C
(50 to 100°F)
Non-Operating
1 1 to 60°C
(34 to 140°F)
Humidity
Operating
Non-Operating
Noncondensing
8 to 80%
8 to 80%
Wet Bulb Requirements
⁶
23°C (73°F)
23°C (73°F)
Noise Emissions
1,2
Operating
Idle
L
WAd
6.9 bels
6.8 bels
L
pAm
N/A
N/A
<L
pA
>
m
49.5 dBA
49.0 dBA
Impulsive or prominent discrete tones
None
None
Clearances
Front
Back
Left
Right
Install/Air Flow
Maintenance of a proper service clearance should allow proper air flow.
Service
See “Service Clearances for System in an S70, S7A, or S80 I/O Rack” on
page 54. Or, see “Service Clearances for S80 or S85 System With T00
Style I/O Rack” on page 36.
1. See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
2. Noise emissions data for Model S80 are based on a system with the doors closed.
3. Inrush currents occur only at initial application of power, no inrush occurs during normal power off-on cycle.
4. The use of the PCI SSA Multi-Initiater/RAID EL in the Model S7A and S80 I/O Drawer 10 EIA limits the system
usage to a 28°C (82°F) environment maximum.
5. The upper limit of the dry bulb temperature must be derated 1 degree C per 137M (450 ft.) above 1295M (4250
ft.)
6. The upper limit of the wet bulb temperature must be derated 1 degree C per 274M (882 ft.) elevation above
1370M (4500 ft.)
Chapter 2. Physical Characteristics of Systems
47
Summary of Contents for 7012 397
Page 1: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 2: ......
Page 3: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 11: ...Appendix Notices 385 Index 387 Contents ix...
Page 12: ...x Site and Hardware Planning Information...
Page 16: ...xiv Site and Hardware Planning Information...
Page 18: ...xvi Site and Hardware Planning Information...
Page 26: ...8 Site and Hardware Planning Information...
Page 238: ...220 Site and Hardware Planning Information...
Page 246: ...228 Site and Hardware Planning Information...
Page 284: ...266 Site and Hardware Planning Information...
Page 296: ...278 Site and Hardware Planning Information...
Page 366: ...348 Site and Hardware Planning Information...
Page 372: ...Async Adapter Cable Planning Chart 354 Site and Hardware Planning Information...
Page 377: ...Standard I O Cable Planning Chart Chapter 12 Cable Planning 359...
Page 380: ...Cable Planning Chart Other Adapters 362 Site and Hardware Planning Information...
Page 384: ...366 Site and Hardware Planning Information...
Page 402: ...384 Site and Hardware Planning Information...
Page 404: ...386 Site and Hardware Planning Information...
Page 413: ......
Page 414: ...Printed in USA SA38 0508 20...
Page 415: ...Spine information RS 6000 and Eserver pSeries Site and Hardware Planning Information...