Declared Acoustical Noise Emissions
Eserver
pSeries 655Product
Configuration
Declared A-Weighted Sound Power
Level, L
WAd
(B)
Declared A-Weighted Sound Pressure
Level, LpAm (dB)
Operating
Idle
Operating
Idle
One processor node (16 max.),
nominal conditions,
non-acoustical doors
7.4
7.4
57
57
One processor node (16 max.)
nominal conditions, acoustical
doors
6.7
(4)
6.7
(4)
50
(4)
50
(4)
Typical configuration of (3
processor nodes, bulk power, 1
I/O drawer), nominal conditions,
non-acoustical doors
8.2
8.2
64
64
Typical configuration of (3
processor nodes, bulk power, 1
I/O drawer), nominal conditions,
acoustical doors
7.5
(4)
7.5
(4)
57
(4)
57
(4)
Maximum configuration of (16
processor nodes, bulk power),
nominal conditions,
non-acoustical doors
8.7
(3)
,
(4)
8.7
(3)
,
(4)
69
(3)
,
(4)
69
(3)
,
(4)
Maximum configuration of (16
processor nodes, bulk power),
nominal conditions, acoustical
doors
8.0
(3)
,
(4)
8.0
(3)
,
(4)
62
(3)
,
(4)
62
(3)
,
(4)
Notes:
1.
L
WAd
is the upper-limit A-weighted sound level;
LpAm
is the mean A-weighted sound pressure level measured at
the 1-meter bystander positions; 1 B = 10 dB.
2. All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296.
3.
Attention:
Your server installation may be subject to government regulations (such as those prescribed by
OSHA or European Community Directives) that cover noise-level exposure in the workplace. The
Eserver
pSeries 7040-W42 rack is available with an optional-acoustical-door feature. This feature can reduce the
likelihood of exceeding the noise-level-exposure limits for racks that are
″
densly populated
″
with
Eserver
pSeries 7039-651 processor nodes. The actual sound-pressure levels in your installation will depend on a variety
of factors, including the number of racks that are installed; the size, materials, and configuration of the room
where the racks are installed; the noise levels from other equipment; the room ambient temperature; and
employees’ location in relation to the equipment. It is recommended that a qualified person, such as an industrial
hygienist, be consulted to determine if the sound-pressure levels that employees may be exposed to exceed
regulatory limits.
4. These numbers are based on preliminary data and are subject to change.
Environmental Specifications
Environmental Specification
Operating
Non-Operating
Storage
Shipping
Temperature
10 to 32°C
(50 to 90°F)
10 to 43°C
(50 to 109°F)
1 to 60°C
(34 to 140°F)
–40 to 60°C
(–40 to 140°F)
Relative Humidity
(Noncondensing)
8 to 80 %
8 to 80 %
5 to 80 %
5 to 100 %
Maximum Wet Bulb
23°C (73°F)
27°C (73°F)
29°C (84°F)
29°C (84°F)
Chapter 2. Physical Characteristics of Systems
97
Summary of Contents for 7012 397
Page 1: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 2: ......
Page 3: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 11: ...Appendix Notices 385 Index 387 Contents ix...
Page 12: ...x Site and Hardware Planning Information...
Page 16: ...xiv Site and Hardware Planning Information...
Page 18: ...xvi Site and Hardware Planning Information...
Page 26: ...8 Site and Hardware Planning Information...
Page 238: ...220 Site and Hardware Planning Information...
Page 246: ...228 Site and Hardware Planning Information...
Page 284: ...266 Site and Hardware Planning Information...
Page 296: ...278 Site and Hardware Planning Information...
Page 366: ...348 Site and Hardware Planning Information...
Page 372: ...Async Adapter Cable Planning Chart 354 Site and Hardware Planning Information...
Page 377: ...Standard I O Cable Planning Chart Chapter 12 Cable Planning 359...
Page 380: ...Cable Planning Chart Other Adapters 362 Site and Hardware Planning Information...
Page 384: ...366 Site and Hardware Planning Information...
Page 402: ...384 Site and Hardware Planning Information...
Page 404: ...386 Site and Hardware Planning Information...
Page 413: ......
Page 414: ...Printed in USA SA38 0508 20...
Page 415: ...Spine information RS 6000 and Eserver pSeries Site and Hardware Planning Information...