2105 Model B09 Versatile Storage Server
™
Dimensions
Height
1780 mm
70.0 in.
Width
840 mm
33.0 in.
Depth
1305 mm
51.0 in.
Weight
746 kg
1640 lbs.
Electrical
Power source loading
3.4 kVA
Power factor
0.9
Voltage range (V ac)
200 to 480
Frequency (hertz)
50 or 60
Thermal output
(Maximum)
11600 Btu/hr
Maximum altitude
2135 m (7000 ft.)
Temperature
Requirements
(See note)
Operating
10 to 38°C
(50 to 90°F)
Non-Operating
10 to 43°C
(50 to 110°F)
Humidity
Requirements
Operating
Non-Operating
(Noncondensing)
8 to 80%
8 to 80%
Wet Bulb
23°C (73°F)
27°C (80°F)
Noise Emissions
¹
Operating
L
WAd
7.6 bels
Clearances
Front
Back
Left
Right
Service
1145 mm(45 in)
810 mm (32 in)
N/A
N/A
1. See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
Note:
The recommended operating temperature is 22°C (72°F) or lower. At lower temperatures, the risk of failure in
the unit is reduced. If the operating temperature is above 22°C (72°F) for long periods of time, the unit will be
exposed to a greater risk of failure from external causes.
238
Site and Hardware Planning Information
Summary of Contents for 7012 397
Page 1: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 2: ......
Page 3: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 11: ...Appendix Notices 385 Index 387 Contents ix...
Page 12: ...x Site and Hardware Planning Information...
Page 16: ...xiv Site and Hardware Planning Information...
Page 18: ...xvi Site and Hardware Planning Information...
Page 26: ...8 Site and Hardware Planning Information...
Page 238: ...220 Site and Hardware Planning Information...
Page 246: ...228 Site and Hardware Planning Information...
Page 284: ...266 Site and Hardware Planning Information...
Page 296: ...278 Site and Hardware Planning Information...
Page 366: ...348 Site and Hardware Planning Information...
Page 372: ...Async Adapter Cable Planning Chart 354 Site and Hardware Planning Information...
Page 377: ...Standard I O Cable Planning Chart Chapter 12 Cable Planning 359...
Page 380: ...Cable Planning Chart Other Adapters 362 Site and Hardware Planning Information...
Page 384: ...366 Site and Hardware Planning Information...
Page 402: ...384 Site and Hardware Planning Information...
Page 404: ...386 Site and Hardware Planning Information...
Page 413: ......
Page 414: ...Printed in USA SA38 0508 20...
Page 415: ...Spine information RS 6000 and Eserver pSeries Site and Hardware Planning Information...