Cable Measuring
Accurate measuring of cables is critical to a successful and efficient installation. Do not guess or estimate
your cable lengths.
In determining the cable lengths you need, be sure to consider the following:
v
A=length allowed for service access, 51 mm (2 ft.) on both system unit and device ends.
v
B=length from system unit to floor.
– Tabletop to floor for desktop models.
– 46 mm (1.5 ft.) for deskside units.
– See
″
7015 Considerations
″
for rack-mounted system units.
v
C=horizontal and vertical cable runs. Be sure to route cables around furniture to avoid tripping hazards.
v
D=distance from floor to device. (This can include distance between floors, between buildings, and so
on, depending on complexity of installation.)
7015 Considerations
The 78-pin multiport interface cables for the 8-or 16-port Async Adapters when used with the 7015 Models
R10 and R20 attach to the system tailgate connect rather than to the adapter itself. Internal cables not
shown in the following cable diagram run from the adapter through the cable management arm to the
tailgate connector. You should begin your cable-measurements at the tailgate connector for the 8-or
16-port Async Adapter multiport cables.
Other cables used with the 7015 Models R10 and R20 are routed through a cable management arm. The
management arm is designed to ensure that the cables do not kink, stretch, or accidentally disconnect
when a drawer is pulled out for service.
When planning the necessary lengths of cables routed through this arm, add 2.3 m (7.5 ft.) to the
measured distance from the base of the rack.
350
Site and Hardware Planning Information
Summary of Contents for 7012 397
Page 1: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 2: ......
Page 3: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 11: ...Appendix Notices 385 Index 387 Contents ix...
Page 12: ...x Site and Hardware Planning Information...
Page 16: ...xiv Site and Hardware Planning Information...
Page 18: ...xvi Site and Hardware Planning Information...
Page 26: ...8 Site and Hardware Planning Information...
Page 238: ...220 Site and Hardware Planning Information...
Page 246: ...228 Site and Hardware Planning Information...
Page 284: ...266 Site and Hardware Planning Information...
Page 296: ...278 Site and Hardware Planning Information...
Page 366: ...348 Site and Hardware Planning Information...
Page 372: ...Async Adapter Cable Planning Chart 354 Site and Hardware Planning Information...
Page 377: ...Standard I O Cable Planning Chart Chapter 12 Cable Planning 359...
Page 380: ...Cable Planning Chart Other Adapters 362 Site and Hardware Planning Information...
Page 384: ...366 Site and Hardware Planning Information...
Page 402: ...384 Site and Hardware Planning Information...
Page 404: ...386 Site and Hardware Planning Information...
Page 413: ......
Page 414: ...Printed in USA SA38 0508 20...
Page 415: ...Spine information RS 6000 and Eserver pSeries Site and Hardware Planning Information...