7248 Model 43P
Dimensions
Desktop
Deskside
Height
160 mm
6.3 in.
420 mm
16.5 in.
Width
¹
420 mm
16.5 in.
160 mm
6.3 in.
Depth
454 mm
17.7 in.
454 mm
17.7 in.
Weight
Minimum
13.2 kg 29 lbs.
Maximum
15.9 kg 35 lbs.
Electrical
Power source loading
0.23
(typical in kVA)
Voltage range (V ac)
100 to 127 or 200 to 240 (switchable)
Frequency (hertz)
50 or 60
Thermal output (maximum)
510 Btu/hr
Thermal output (minimum)
225 Btu/hr
Power requirements (maximum)
150 watts
Power factor
0.5 to 0.7
Inrush current
⁶
23 amps at 120 V ac, 23 amps at 240 V ac
Maximum altitude
2135 m (7000 ft.)
Temperature Requirements
Operating
16 to 32°C
(60 to 90°F)
Non-Operating
10 to 43°C
(50 to 110°F)
Humidity Requirements
Operating
Non-Operating
(Noncondensing)
8 to 80%
8 to 80%
Wet Bulb
23°C (73°F)
27°C (80°F)
Noise Emissions
¹
Operating
Idle
L
WAd
5.2 bels
5.0 bels
L
pAm
41 dBA
38 dBA
<L
pA
>
m
36 dBA
34 dBA
Impulsive or prominent discrete tones
No
No
Clearances
³
Front
Back
Left
Right
Install/Air Flow
⁴⁵
35mm(1.5 in)
51mm(2 in)
25mm(1 in)
25mm(1 in)
Service
466mm(18 in)
N/A
N/A
N/A
Footprint
4
Width
Depth
Desktop
470mm(18.5 in)
537mm(21.1 in)
Deskside
211mm(8.3 in)
537mm(21.1 in)
1. Width measurement includes the optional vertical stand.
2. See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
3. Left and right measurements apply only when the system is used in the desktop position.
4. The amount of space needed by the unit during normal operation is indicated by the footprint dimensions.
5. When placed in the vertical position, the system requires 25 mm (1 in) at the bottom and top for proper air flow.
The necessary bottom clearance is provided by the optional vertical stand.
6. Inrush currents occur only at initial application of power, no inrush occurs during normal power off-on cycle.
208
Site and Hardware Planning Information
Summary of Contents for 7012 397
Page 1: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 2: ......
Page 3: ...RS 6000 and Eserver pSeries Site and Hardware Planning Information SA38 0508 20...
Page 11: ...Appendix Notices 385 Index 387 Contents ix...
Page 12: ...x Site and Hardware Planning Information...
Page 16: ...xiv Site and Hardware Planning Information...
Page 18: ...xvi Site and Hardware Planning Information...
Page 26: ...8 Site and Hardware Planning Information...
Page 238: ...220 Site and Hardware Planning Information...
Page 246: ...228 Site and Hardware Planning Information...
Page 284: ...266 Site and Hardware Planning Information...
Page 296: ...278 Site and Hardware Planning Information...
Page 366: ...348 Site and Hardware Planning Information...
Page 372: ...Async Adapter Cable Planning Chart 354 Site and Hardware Planning Information...
Page 377: ...Standard I O Cable Planning Chart Chapter 12 Cable Planning 359...
Page 380: ...Cable Planning Chart Other Adapters 362 Site and Hardware Planning Information...
Page 384: ...366 Site and Hardware Planning Information...
Page 402: ...384 Site and Hardware Planning Information...
Page 404: ...386 Site and Hardware Planning Information...
Page 413: ......
Page 414: ...Printed in USA SA38 0508 20...
Page 415: ...Spine information RS 6000 and Eserver pSeries Site and Hardware Planning Information...