Error Messages
POST Message
Description
1762
A hard disk drive configuration error occurred.
Action:
1. Make sure that the cables are securely attached to
all drives.
2. Make sure that the settings for the drive options
are correct in the Configuration/Setup utility
program. If the settings are not correct, change
them. For instructions on using the
Configuration/Setup utility program, see
Chapter 2, “Configuring Your Server” on page 15.
178X
A failure occurred during testing of the hard disk drive.
Action: Run the system diagnostic tests.
1800
A PCI adapter has requested a hardware interrupt that is not
available.
Action:
1. Make sure that the settings for the PCI Adapter
and any ISA legacy adapters are correct in the
Configuration/Setup utility program. If the
interrupt resources settings are not correct, change
the settings. For instructions on using the
Configuration/Setup utility program, see
Chapter 2, “Configuring Your Server” on page 15.
2. If all interrupts are being used by ISA legacy
adapters, you might need to remove one to make
an interrupt available to the PCI adapter. For
instructions on removing adapters, see “Removing
Adapters” on page 61.
148
PC Server 315 User's Handbook