Error Messages
POST Message
Description
301
302
303
304
305
A failure occurred during testing of the keyboard and
keyboard controller. These error messages also might be
accompanied by continuous beeping.
Action: Ensure that:
1. Nothing is resting on the keyboard and pressing a
key.
2. No key is stuck.
3. The keyboard cable is connected correctly to the
keyboard and to the correct connector on the
server.
Note: If you have just connected a new mouse or other
pointing device, turn the server off and disconnect that
device. Wait at least 5 seconds, and then turn on the
server. If the error message goes away, replace the
device.
Running the diagnostic tests can isolate the server component
that failed, but you must have your system serviced. If the
error message remains, have the keyboard and cable or the
system serviced.
601
A failure occurred during testing of the diskette drive and
diskette-drive controller. This error can be caused by a loose
or incorrectly connected cable, a failing drive, or a failing
system board.
Action: The server can be used, but one or more diskette
drives might not work. Running the diagnostic tests
can isolate the diskette drive that failed, but you must
have your system serviced.
602
The server cannot start the diskette in the drive. The diskette
might be damaged or formatted incorrectly.
Action: Try another startable diskette that is in working
condition.
604
A failure occurred during the testing of a diskette drive.
Action:
1. Verify that the configuration information in the
Configuration/Setup utility program correctly
reflects the type of diskette drive that you have
installed.
2. Run the diagnostic programs.
3. If the diagnostic programs fail, replace the diskette
drive.