Chapter 3 Operation
3.4 Field Network
Address Map
97
(3) I/O signal assignment
(ON = Applicable bit is “1”, OFF = Applicable bit is “0”)
Signal Type
Bit
Symbol
Description
Details
b15
BKRL
Brake release
ON: Brake release, OFF: Brake activated
3.6 (17)
b14
b13
–
Cannot be used.
–
b12
SON
Servo ON command
ON: Servo ON, OFF: Servo OFF
3.6 (5)
b11
RES
Reset
A reset is performed when this signal turns ON.
3.6 (4)
b10
STP
Pause
ON: Pause, OFF: Pause release
3.6 (10)
b9
HOME
Home return
Home-return command with this signal ON,
command carried on till complete even if the
signal is turned OFF on the way
3.6 (6)
b8
CSTR
Positioning start
Movement command executed with this signal
ON, command carried on till complete even if
the signal is turned OFF on the way
3.6 (7)
b7
PC128
b6
PC64
b5
PC32
b4
PC16
b3
PC8
b2
PC4
b1
PC2
PLC Input
Control
Signal/
Specified
Position
No.
b0
PC1
8 bits binary data
Available range for Setting: 0 to 255
To operate, it is necessary to have the position
data that the operation conditions are already
set in advance with a teaching tool such as the
PC software.
In this register, indicate the position number the
data is input with a binary number.
Indicating a value out of the range or operating
with a position number with no setting
conducted will generate the alarm code 0A2
“Position Data Error”.
3.6 (23)
b15
EMGS
This signal turns ON during an emergency stop
3.6 (2)
b14
ZONE1
“ON” for the current position within the zone 1
set range
The zone range setting is necessary for the
parameter.
3.6 (11)
b13
PSFL
This signal turns ON when the actuator missed
the load in push-motion operation.
3.6 (20)
b12
SV
This signal turns ON when operation standby is
complete (Servo is ON).
3.6 (5)
b11
ALM
This signal is ON while an alarm is generated.
3.6 (3)
b10
MOVE
This signal is ON while in movement.
3.6 (8)
b9
HEND
This signal turns ON at home return complete
and is kept unless the home position is lost due
to a factor such as an alarm.
3.6 (6)
b8
PEND
This signal turns ON at positioning complete
and is kept ON during a stop with the servo ON,
but does not turn ON when pressing operation is
failed.
3.6 (9)
b7
PM128
b6
PM64
b5
PM32
b4
PM16
b3
PM8
b2
PM4
b1
PM2
PLC Output
Status
Signal/
Completed
Position
No.
b0
PM1
8 bits binary data
The positioning complete position number is
output in a binary number once getting into the
positioning width after moving to the target
position.
In the case that the position movement has not
been performed at all, or during the movement,
“0” is output. Read it by turning PEND Signal
ON after movement.
3.6 (23)
ME0302-4A
Summary of Contents for ERC3
Page 1: ...IAI Corporation ERC3 Gateway Unit Instruction Manual Forth Edition ...
Page 2: ......
Page 4: ...ME0302 4A ...
Page 8: ...ME0302 4A ...
Page 35: ...Chapter 1 Specifications Check 1 6 Option 27 1 6 Option はケーブル長 ME0302 4A ...
Page 54: ...Chapter 2 Wiring 2 3 Wiring Method 46 ME0302 4A ...
Page 158: ...Chapter 3 Operation 3 8 Field Network LED Indication 150 ME0302 4A ...
Page 160: ...Chapter 4 I O Parameter 152 ME0302 4A ...
Page 176: ...Chapter 5 Troubleshooting 5 4 Alarm List 168 ME0302 4A ...
Page 186: ......
Page 187: ......