Chapter 3 Operation
3.2 Initial Setting
54
[Step 8]
Click on a blank cell and “*” shows up. “*” mark means that an operation mode is
selected for each axis.
If clicking a cell showing “*”, the mark turns to “(*)”.
“(*)” means it is a reserved axis,
which is to be set when not using even though the actuator is connected.
If clicking on a cell with “(*)” mark for the reserved axes shown, the cell turns back to
blank.
(Note) Even if the total number of the used axes is an odd number, make the last axis in
reservation to get an even number.
[Step 9]
Write the edited operation mode setting parameters to ERC3 gateway unit.
Click on the “Write” button shown below and a confirmation window pops up. Click on
the “Yes” button.
If the writing is finished in normal condition, writing complete window appears. Click
OK.