Chapter 3 Operation
3.4 Field Network
Address Map
94
(ON = Applicable bit is “1”, OFF = Applicable bit is “0”)
Signal Type
Bit
Symbol
Description
Details
Completed
position No.
(Simple alarm
code)
16 bits
PM1 to
PM256
16-bit integer
The positioning complete position number is
output in a binary number once getting into the
positioning width after moving to the target
position.
In the case that the position movement has not
been performed at all, or during the movement,
“0” is output. Read it by turning PEND Signal
ON after movement.
The simple alarm code (refer to Chapter 5.
Troubleshooting) is output while an alarm is
issued (ALM of Status Signal is ON).
3.6 (23)
b15
EMGS
This signal turns ON during an emergency stop 3.6 (2)
b14
CRDY
This signal turns ON when the controller is
standing by.
3.6 (1)
b13
ZONE2
“ON” for the current position within the zone 2
set range
The zone range setting is necessary for the
parameter.
b12
ZONE1
“ON” for the current position within the zone 1
set range
The zone range setting is necessary for the
parameter.
3.6 (11)
b11
PZONE
Position zone (Invalid in Simple Direct Mode)
This signal turns ON when the current position
is inside the specified position zone.
3.6 (11)
b10
MODES
Teaching mode Signal (Invalid in Simple Direct
Mode)
This signal is ON while the teaching mode is
selected.
3.6 (15)
b9
WEND
Position data import complete (Invalid in
Simple Direct Mode)
This signal turns ON when writing is complete.
3.6 (16)
b8
b7
b6
–
Cannot be used.
–
b5
PSFL
This signal turns ON when the actuator missed
the load in push-motion operation.
3.6 (20)
b4
SV
This signal turns ON when operation standby is
complete (Servo is ON).
3.6 (5)
b3
ALM
This signal is ON while an alarm is generated.
3.6 (3)
b2
MOVE
This signal is ON while in movement.
3.6 (8)
b1
HEND
This signal turns ON at home return complete
and is kept unless the home position is lost due
to a factor such as an alarm.
3.6 (6)
PLC Output
Status Signal
b0
PEND
This signal turns ON at positioning complete
and is kept ON during a stop with the servo
ON, but does not turn ON when pressing
operation is failed.
3.6 (9)
ME0302-4A
Summary of Contents for ERC3
Page 1: ...IAI Corporation ERC3 Gateway Unit Instruction Manual Forth Edition ...
Page 2: ......
Page 4: ...ME0302 4A ...
Page 8: ...ME0302 4A ...
Page 35: ...Chapter 1 Specifications Check 1 6 Option 27 1 6 Option はケーブル長 ME0302 4A ...
Page 54: ...Chapter 2 Wiring 2 3 Wiring Method 46 ME0302 4A ...
Page 158: ...Chapter 3 Operation 3 8 Field Network LED Indication 150 ME0302 4A ...
Page 160: ...Chapter 4 I O Parameter 152 ME0302 4A ...
Page 176: ...Chapter 5 Troubleshooting 5 4 Alarm List 168 ME0302 4A ...
Page 186: ......
Page 187: ......