Chapter 2 Wiring
2.3 Wiring Method
42
2) CC-Link Type
Connector Name
CC-Link Connector
Cable Side
MSTB2.5/5-STF-5.08 AU
Enclosed in standard
package
Manufactured by PHOENIX
CONTACT
Controller Side
MSTB2.5/5-GF-5.08 AU
Pin
No.
Signal Name
(Color)
Description
Applicable cable
diameter
1 DA (BL)
Communication line A
2 DB (WT)
Communication line B
3 DG (YW)
Digital GND
4 SLD
Connect the shield of the shielded
cable (Connect the FG of the 5 pins
and controller FG internally)
5 FG
Frame Ground
(Connect the SLD of the 4 pins and
controller FG internally)
Dedicated cable for
CC-Link
Note Connect a terminal resistor between DA and DB if the unit comes to the
end of the network. [Refer to 2.2 [4] Wiring Layout of Field Network]
1
2
3
4
5
WT (DB)
BL (DA)
Shield (SLD)
YW (DG)
Front view of
connector on
controller side
ME0302-4A