Chapter 2 Wiring
2.3 Wiring Method
45
6) MECHATROLINK Type
Connector Name
MECHATROLINK Connector
Cable Side
Prepare a connector complied with MECHATROLINK
standards.
Controller Side
DUSB-ARB82-T11A-FA
Manufactured by DDK
Note Connect a terminal resistor (JEPMC-W6022) between DATA and
/DATA if the unit comes to the end of the network. [Refer to 2.2 [4]
Wiring Layout of Field Network]
7) EtherCAT Type
Connector Name
EtherCAT Connector
Cable Side
8P8C Modular Plug
Controller Side
8P8C Modular Jack
Pin
No.
Signal Name
(Color)
Description
Applicable cable
diameter
1
TD+
Sent data +
2
TD-
Sent data -
3
RD+
Received data +
4
–
Not used
5
–
Not used
6
RD-
Received data -
7
–
Not used
8
–
Not used
For EtherNet cable,
use a straight STP
cable that
possesses the
performance of
Category 5 or
more.
Pin
No.
Signal Name
(Color)
Description
Applicable cable
diameter
A1/B1 NC
Disconnected
A2/B2 /DATA
Signal line - side
A3/B3 DATA
Signal line + side
A4/B4 SH
Shield
MECHATROLINK
Dedicated Cable
Front view of
connector on
controller side
8
1
Front view of
connector on
controller side
8
1
B1
A1
A4
B4
ME0302-4A
Summary of Contents for ERC3
Page 1: ...IAI Corporation ERC3 Gateway Unit Instruction Manual Forth Edition ...
Page 2: ......
Page 4: ...ME0302 4A ...
Page 8: ...ME0302 4A ...
Page 35: ...Chapter 1 Specifications Check 1 6 Option 27 1 6 Option はケーブル長 ME0302 4A ...
Page 54: ...Chapter 2 Wiring 2 3 Wiring Method 46 ME0302 4A ...
Page 158: ...Chapter 3 Operation 3 8 Field Network LED Indication 150 ME0302 4A ...
Page 160: ...Chapter 4 I O Parameter 152 ME0302 4A ...
Page 176: ...Chapter 5 Troubleshooting 5 4 Alarm List 168 ME0302 4A ...
Page 186: ......
Page 187: ......