3.4 Wiring connections (for connectors)
3-8
3. Wiring
~
Two-Circuit power supply specification TMD2 (Option)
Connect the power wiring to the power I/O connector.
Connect the to wiring to the connector terminal block while referring to the connection
diagram.
Connect the [B1] connector terminal and the +24 V (Driving Source) terminal of
the 24 V DC power supply.
Connect the [A2] connector terminal and the +24 V (Control) terminal of
the 24 V DC power supply.
Connect the [A1] connector terminal and the 0 V terminal of
the 24 V DC power supply.
(Note) Wire for 24V (control) on A2 can apply 0.3mm
2
(AWG22).
When establishing an external stop switch, add a b-contact switch to the [B1] terminal wiring.
This shuts off the 24 V (Driving Source) power supply in the stopped state (drive power OFF).
Pin
No.
Connector
nameplate
name
Compatible
wire
diameter
Required specifications
B1
24 V
(Driving
Source)
KIV 0.75 mm
2
(AWG18)
Power supply voltage: 24 V DC ±10%
Power capacity:
RTC12 Rated 3.5 A, max. 4.2 A
RTC9 Max. 2.0 A
(Including control power supply
0.3 A)
Wiring length: 10 m or less
A2
24 V
(Control)
A1
0 V
1
3
1
2
A1
B1
A2
0 V
1
3
+24 V
2
+24 V
Reference
3
24 V DC power supply
connection diagram
Before starting connector wiring,
check the details on pages 3-10 to 11
Power I/O connector
Summary of Contents for ELECYLINDER EC-RTC12
Page 2: ......
Page 26: ...1 5 Accessories 1 35 Power I O cable 1 35 Power I O connector 1 36 ...
Page 64: ......
Page 78: ...2 14 2 Installation ...
Page 80: ......
Page 100: ...3 20 3 Wiring ...
Page 124: ...4 22 4 Operation ...
Page 126: ......
Page 132: ...5 6 5 Preventive Predictive Maintenance ...
Page 134: ......
Page 148: ...6 14 6 Parameters ...
Page 150: ......
Page 168: ...7 18 7 Troubleshooting ...
Page 170: ......
Page 208: ......
Page 212: ......
Page 214: ...10 2 10 Life ...
Page 216: ......
Page 219: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 220: ......
Page 225: ......