1.3 Operating conditions
1-29
1. Specifications
Step 2 Check the load moment and thrust load
Make sure that the load moment and thrust load applied to the output shaft are within the
allowable values. Use above the allowable range could cause drop of the product life or may
cause malfunction.
Model
Allowable load moment
(N·
m
)
Allowable thrust load
(N)
RTC9
5
50
RTC12
18
(12 in vertical orientation or
horizontally oriented wall mount)
400
Thrust load
Load moment
Load moment datum position
RTC9 : 15 mm
RTC12 : 17 mm
Output shaft