6.4 Parameter function descriptions
6-10
6. Parameter
s
Parameter No. 5: Smooth accel/decel setting
No. Category
Name
Symbol
Unit
Input range Default setting
at shipping
5
A
Smooth
accel/decel setting
MOD0
-
Disabled,
enabled
Disabled
● The movement waveform for ELECYLINDER operation can be selected.
● When [Enabled], accel/decel operation becomes smoother (less abrupt).
This softens the shocks of acceleration/deceleration without delaying the operation time.
● If [Disabled], the above functionality is not enabled.
Caution
For operation in which the acceleration time or deceleration time exceeds 2 seconds,
do not [Enable] "smooth accel/decel settings".
Normal operation will not be possible.
Avoid momentary stops during acceleration or deceleration operation.
Sudden changes (acceleration) will occur, which may be dangerous.
Setting
Acceleration/deceleration
pattern
Operation waveform image
Disabled
Trapezoid
Enabled
S-motion
Time
Speed
Speed
Time
Summary of Contents for ELECYLINDER EC-RTC12
Page 2: ......
Page 26: ...1 5 Accessories 1 35 Power I O cable 1 35 Power I O connector 1 36 ...
Page 64: ......
Page 78: ...2 14 2 Installation ...
Page 80: ......
Page 100: ...3 20 3 Wiring ...
Page 124: ...4 22 4 Operation ...
Page 126: ......
Page 132: ...5 6 5 Preventive Predictive Maintenance ...
Page 134: ......
Page 148: ...6 14 6 Parameters ...
Page 150: ......
Page 168: ...7 18 7 Troubleshooting ...
Page 170: ......
Page 208: ......
Page 212: ......
Page 214: ...10 2 10 Life ...
Page 216: ......
Page 219: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 220: ......
Page 225: ......