3.3 Connection arrangement diagram
3-5
3. Wiring
3.3 Connection arrangement diagram
Here the wiring connection method with a power I/O connector is introduced.
Caution
[Note 1] This switch releases the brake forcibly for actuators equipped with a brake.
The switch power capacity requires 24 V DC ±10% and 200 mA or more.
[*ALM] is a b-contact (active-low) signal.
The output signal is ON in normal conditions and OFF when an alarm occurs.
[For PNP specification]
Backward complete
[For NPN specification]
Forward complete
Alarm
Backward complete
Forward complete
Note 1
Brake release
ELECYLINDER (NPN specification)
B2
Power I/O connector
A1
B3
B5
B4
A3
A4
A5
0 V
BKRLS
ST0
ST1
RES
* ALM
LS0
LS1
0 V
24 V DC
Ground
Alarm clear
B1
24 V
24 V power supply
Backward
Forward
Note 1
B1
B3
B5
B2
B4
A3
A4
A5
24 V
BKRLS
ST0
ST1
RES
* ALM
LS0
LS1
0 V
24 V DC
Brake release
24 V power supply
Alarm clear
Alarm
A1
0 V
Ground
Backward
Forward
ELECYLINDER (PNP specification)
Power I/O connector
Summary of Contents for ELECYLINDER EC-RTC12
Page 2: ......
Page 26: ...1 5 Accessories 1 35 Power I O cable 1 35 Power I O connector 1 36 ...
Page 64: ......
Page 78: ...2 14 2 Installation ...
Page 80: ......
Page 100: ...3 20 3 Wiring ...
Page 124: ...4 22 4 Operation ...
Page 126: ......
Page 132: ...5 6 5 Preventive Predictive Maintenance ...
Page 134: ......
Page 148: ...6 14 6 Parameters ...
Page 150: ......
Page 168: ...7 18 7 Troubleshooting ...
Page 170: ......
Page 208: ......
Page 212: ......
Page 214: ...10 2 10 Life ...
Page 216: ......
Page 219: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 220: ......
Page 225: ......