4.4 I/O signals
4-15
4. Operation
[LS0] [LS1] signals: Position detection output (backward end / forward end)
● The LS signals perform the same operation as an air cylinder automatic switch.
They are not positioning complete signals.
● The LS signals turn ON when the current ELECYLINDER position is within the detection
range configured at the backward and forward ends.
● They turn ON when within the detection range regardless of whether the servo is ON or
OFF.
The backward end and forward end
set values' relationship to [LS0]
and [LS1] signals ON is as follows.
In this example, the LS signal
detection range is ±0.10 degrees.
To adjust the LS signal detection range,
open the [Edit parameters window].
Parameter No.2
[Auto switch LS signal detection range
adjustment] can be used to make
adjustments.
Forward end
330.00 degrees
Backward end
0.00 degrees
Summary of Contents for ELECYLINDER EC-RTC12