![IAI ELECYLINDER EC-RTC12 Instruction Manual Download Page 140](http://html1.mh-extra.com/html/iai/elecylinder-ec-rtc12/elecylinder-ec-rtc12_instruction-manual_604098140.webp)
6.4 Parameter function descriptions
6-6
6. Parameter
s
0.30 degrees
80.00 degrees
(Used rotation angle)
0.30 degrees
Parameter No. 1:
80.00 degrees
6.4 Parameter function descriptions
Parameter No. 1: Operation range adjustment
No. Category
Name
Symbol
Unit
Input range
Default setting
at shipping
1
A
Operation range
adjustment
LI
degree
0 to 9999.69
Maximum
rotation angle
● The ELECYLINDER operation range can be adjusted to suit your system.
● The minimum setting unit is 0.01 degrees.
● Set up an angle that you would like to use.
The controller automatically adds 0.30 degrees and controls/monitors the operation range.
Set the operating rotation angle
between 0 and 80 degrees
by changing [Parameter No. 1]
to [80.00 degrees].
Caution
Set within the ELECYLINDER movable range.
Setting to a value that exceeds the maximum rotation angle will result in collision with
the forward side mechanical stopper.
This may damage the ELECYLINDER, workpiece or peripheral devices.
Configuration example
Summary of Contents for ELECYLINDER EC-RTC12
Page 2: ......
Page 26: ...1 5 Accessories 1 35 Power I O cable 1 35 Power I O connector 1 36 ...
Page 64: ......
Page 78: ...2 14 2 Installation ...
Page 80: ......
Page 100: ...3 20 3 Wiring ...
Page 124: ...4 22 4 Operation ...
Page 126: ......
Page 132: ...5 6 5 Preventive Predictive Maintenance ...
Page 134: ......
Page 148: ...6 14 6 Parameters ...
Page 150: ......
Page 168: ...7 18 7 Troubleshooting ...
Page 170: ......
Page 208: ......
Page 212: ......
Page 214: ...10 2 10 Life ...
Page 216: ......
Page 219: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 220: ......
Page 225: ......