6.4 Parameter function descriptions
6-13
6. Parameter
s
Parameter No. 8: Power-saving setting
No. Category
Name
Symbol
Unit
Input range Default setting
at shipping
8
A
Power-saving
setting
BUEN
-
Disabled,
enabled
Disabled
● Either Enabled or Disabled can be selected for the ELECYLINDER power-saving setting.
● When "Enabled," the power capacity can be reduced up to 40% compared to "Disabled"
mode, but the maximum acceleration/deceleration, output torque and allowable moment of
inertia decrease in comparison.
Refer to "Output torque and allowable moment of inertia (Power-saving: Enabled)" on
page 1-13.
● When "Disabled," the maximum acceleration/deceleration, output torque and allowable
moment of inertia increase compared to "Enabled" mode.
Refer to "Output torque and allowable moment of inertia (Power-saving: Disabled)", on
page 1-12.