8.5 Greasing method
8-11
8. Maintenan
ce and Inspection
[Recommended syringe and needle nozzle]
Syringe
Needle nozzle
SS-20LZ (Terumo)
20 ml, lock type
DPN-18G-1 (Musashi Engineering)
Nozzle outer diameter1.27 mm,
needle long 12.7 mm
Caution
Too much grease applied could cause overflow of grease, which may cause troubles
and defects.
If the grease enters your eye, immediately see a specialist physician for appropriate
care.
After finishing the grease replenishment, wash your hands carefully with water and
soap to rinse the grease off.