3.4 Wiring connections (for connectors)
3.5 Wiring connections (for cables)
3-12
3. Wiring
Brake release wiring
For the specification with brake, when installing a forcible brake release switch, connect
wiring to the [B2] connector terminal.
Power capacity of 24 V DC ±10% / 200 mA or higher is required.
Pin
No.
Connector
nameplate
name
Signal
abbreviation
Compatible
wire diameter
Required specifications
B2
Brake release
BKRLS
KIV 0.20 mm
2
(AWG24)
24 V DC ±10% / 200 mA
or higher
3.5 Wiring connections (for cables)
Here the wiring connection method with a power I/O cable is introduced.
Power I/O cable
Note 1 TMD2 is 24 V (control)
(Note) Cable in light green and light gray not in use
(Note1)
ST0
ST1
RES
LS0/PE0
LS1/PS1
*ALM