4.5 Operating method from master device
4-20
4. Operation
Pressing operation: [ST0] [ST1] [PE0] [PE1] signals
Before conducting pressing operation, refer to “
Pressing operation setting
(page 4-10)”
and configure the operating conditions and position settings using the Simple Data Setting screen.
The basic time chart is as follows.
Caution
The pressing operation speed is 20 deg./s.
The workpiece remains pressed after the pressing is completed.
If the workpiece moves or pushes back, it may be pressed even further.
If the workpiece is struck during approach operation, [Alarm group A: Overload alarm]
will be triggered.
→ For details, refer to “
Alarm group A: Overload alarm
(page 7-11).”
ST signal
PE signal
ELECYLINDER
movement
PE signal ON
→ ST signal OFF
Pressing
operation
Approach operation
Not ON at failure
to contact
Pressing complete