1.2 Mechanical specifications
1-21
1. Specifications
Home-return process
The EC rotary type rotates for 330 deg. (mechanical stopper system).
Rotation clockwise should be the positive side rotation from the view at the top of the rotation
portion.
The home-return operation should be performed counterclockwise.
The axis detects the position of the mechanical stopper and stops after rotation
counterclockwise.
It is not available to have the home-return operation clockwise.
* The direction of all the behaviors should be reversed for the home reversed type (NM).
Positive
direction
Range of operation (330 deg.)
Home
position
Mechanical
stopper
Rotary
axis