1.3 Operating conditions
1-25
1. Specifications
[When load torque affects]
Used as shown in the figures below should have the load torque by the gravity work on the
unit, thus the allowable inertia moment drops for the same amount. First, calculate the load
torque and obtain the corrected allowable moment of inertia. Calculate the moment of inertia
in addition to check if it is within the allowable inertia moment.
● Step 1 Calculating the load torque T
T = mgr × 10
-3
[N·m]
m : Loaded weight [kg]
g : Gravitational acceleration [m/s
2
]
r : Distance of load gravity center [mm]
● Step 2 Calculating the allowable moment of inertia correction factor Cj
Cj = (Tmax - T) / Tmax
Tmax : Output torque [N·m]
Example
Load gravity center: offset from center of output shaft
Installation of unit:
Horizontal - horizontally oriented wall mount / vertical orientation
T
(Load torque)
m
(Loaded weight)
Load
gravity center
r
(Distance of load gravity center)
Direction
of gravity
Summary of Contents for ELECYLINDER EC-RTC12
Page 2: ......
Page 26: ...1 5 Accessories 1 35 Power I O cable 1 35 Power I O connector 1 36 ...
Page 64: ......
Page 78: ...2 14 2 Installation ...
Page 80: ......
Page 100: ...3 20 3 Wiring ...
Page 124: ...4 22 4 Operation ...
Page 126: ......
Page 132: ...5 6 5 Preventive Predictive Maintenance ...
Page 134: ......
Page 148: ...6 14 6 Parameters ...
Page 150: ......
Page 168: ...7 18 7 Troubleshooting ...
Page 170: ......
Page 208: ......
Page 212: ......
Page 214: ...10 2 10 Life ...
Page 216: ......
Page 219: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 220: ......
Page 225: ......