8.6 How to replace components
8-17
8. Maintenan
ce and Inspection
4) Pull off the connectors on the cable connecting the controller cover assembly and
the PC board, and then take the end plate off.
* The ring tongue terminal on the internal wiring (frame grounding line) should be
jointly fastened on the end plate.
Hex socket head cap screw
M3 × 10
End plate
Frame grounding line
Connector
PC board