[Situation 3] Shock or vibration is observed in acceleration/deceleration
No.
Possible cause
Confirmation/countermeasure
1
● Acceleration/deceleration setting is too
high.
● A load susceptible to acceleration and
deceleration is mounted.
● The ELECYLINDER is mounted on
equipment with a structure susceptible
to acceleration and deceleration.
● Lower the acceleration/deceleration setting.
● Enable Parameter No. 5 "Smooth
accel/decel setting" and check its effect.
→ For details, refer to "6.4 Parameter function
descriptions".
2
Load inertia is excessive.
Lower the deceleration and suppress
overshoot.
[Situation 4] The unit vibrates slightly while stopped
No.
Possible cause
Confirmation/countermeasure
1
● A load susceptible to vibration is
mounted.
● The ELECYLINDER is mounted on a
frame with a structure susceptible to
vibration.
● Lower the acceleration/deceleration setting.
● If Parameter No. 6 "Current control setting
at stop" is disabled, enable it and check its
effect.
→ For details, refer to "6.4 Parameter function
descriptions".
Summary of Contents for ELECYLINDER EC-RTC12
Page 2: ......
Page 26: ...1 5 Accessories 1 35 Power I O cable 1 35 Power I O connector 1 36 ...
Page 64: ......
Page 78: ...2 14 2 Installation ...
Page 80: ......
Page 100: ...3 20 3 Wiring ...
Page 124: ...4 22 4 Operation ...
Page 126: ......
Page 132: ...5 6 5 Preventive Predictive Maintenance ...
Page 134: ......
Page 148: ...6 14 6 Parameters ...
Page 150: ......
Page 168: ...7 18 7 Troubleshooting ...
Page 170: ......
Page 208: ......
Page 212: ......
Page 214: ...10 2 10 Life ...
Page 216: ......
Page 219: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 220: ......
Page 225: ......