Maintenance warning 3: Overload warning level
This is an alert that the target value of the "overload warning level" set by the customer has
been reached.
No.
Content
Causes and countermeasures
1
Before the ELECYLINDER stops operation due
to the "overload alarm", follow the
troubleshooting procedure and conduct visual
inspection and maintenance.
* To disable this warning, change the
"overload warning level" in "Maintenance
Information" to 100%.
[Causes]
The warning may be caused by the depletion
of grease on the gears inside the
ELECYLINDER, brake failure, motor failure,
contact with peripheral equipment, etc.
[Countermeasure 1]
Have a visual inspection to check on the gears
inside ELECYLINDER for dry-up of grease.
If the grease is dried up, supply grease.
→ For details, refer to "8.5 Greasing method".
[Countermeasure 2]
Remove the motor and check the sliding
movement of the ELECYLINDER body.
If there is no abnormality in the sliding motion,
there is a possibility of motor or brake failure.
Replacement of the motor is recommended.
Customers may not replace the motor by
themselves. Contact IAI.
* For setting, refer to "5.2 Maintenance information" and "5.3 Setting maintenance information".
Summary of Contents for ELECYLINDER EC-RTC12
Page 2: ......
Page 26: ...1 5 Accessories 1 35 Power I O cable 1 35 Power I O connector 1 36 ...
Page 64: ......
Page 78: ...2 14 2 Installation ...
Page 80: ......
Page 100: ...3 20 3 Wiring ...
Page 124: ...4 22 4 Operation ...
Page 126: ......
Page 132: ...5 6 5 Preventive Predictive Maintenance ...
Page 134: ......
Page 148: ...6 14 6 Parameters ...
Page 150: ......
Page 168: ...7 18 7 Troubleshooting ...
Page 170: ......
Page 208: ......
Page 212: ......
Page 214: ...10 2 10 Life ...
Page 216: ......
Page 219: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 220: ......
Page 225: ......