3.5 Wiring connections (for cables)
3-16
3. Wiring
24 V DC power supply wiring
Connect the power wiring to the power I/O cable.
Connect the 24 V DC power supply to the terminal block after terminal-processing the 24 V
and 0 V wires of the power I/O cable.
Connect the 24 V wire (insulation color: red) to the +24 V terminal of
the 24 V DC power supply.
Connect the 0 V wire (insulation color: black) to the 0 V terminal of
the 24 V DC power supply.
Wiring
color
Signal
abbreviation
Function
overview
Required specifications
Red
24 V
Power supply
input
Power supply voltage: 24 V DC ±10%
Power capacity: RTC12 Rated 3.5 A, max. 4.2 A
RTC9 Max. 2.0 A
Black
0 V
Ground
When establishing an external stop switch, add a b-contact switch to the [red] terminal wiring.
This shuts off the 24 V power supply in the stopped state (control/drive power OFF).
1
2
Reference
24 V DC power supply connection diagram
24 V DC power supply
ELECYLINDER / Power I/O cable
1
2
Summary of Contents for ELECYLINDER EC-RTC12
Page 2: ......
Page 26: ...1 5 Accessories 1 35 Power I O cable 1 35 Power I O connector 1 36 ...
Page 64: ......
Page 78: ...2 14 2 Installation ...
Page 80: ......
Page 100: ...3 20 3 Wiring ...
Page 124: ...4 22 4 Operation ...
Page 126: ......
Page 132: ...5 6 5 Preventive Predictive Maintenance ...
Page 134: ......
Page 148: ...6 14 6 Parameters ...
Page 150: ......
Page 168: ...7 18 7 Troubleshooting ...
Page 170: ......
Page 208: ......
Page 212: ......
Page 214: ...10 2 10 Life ...
Page 216: ......
Page 219: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 220: ......
Page 225: ......