4.4 I/O signals
4-12
4. Operation
4.4 I/O signals
I/O signal list
ELECYLINDER I/O signals are as follows.
Category
Signal name
Signal
abbreviation
Function overview
Input
Backward
ST0
Turning ON sends it backward.
Turning OFF midway through operation will cause
a gradual stop.
Turning ON when home return is not complete
triggers home return operation.
Turning OFF midway through operation will cause
a gradual stop.
Forward
ST1
Turning ON sends it forward.
Turning OFF midway through operation will cause
a gradual stop.
Turning ON when home return is not complete
triggers home return operation.
Turning OFF midway through operation will cause
a gradual stop.
Alarm clear
RES
Turning ON resets the alarm.
Brake release
BKRLS
Inputting 24 V DC releases the brake.
Output
Backward complete /
Pressing complete
LS0/PE0
ON when entering the backward end detection
range.
ON when pressing operation is complete.
Forward complete /
Pressing complete
LS1/PE1
ON when entering the forward end detection
range.
ON when pressing operation is complete.
Alarm
(b-contact)
* ALM
ON in normal conditions.
OFF when an alarm occurs.
Caution
When home return is complete and when it is not, the [ST0] signal and [ST1] signal
have different functions.
Summary of Contents for ELECYLINDER EC-RTC12
Page 2: ......
Page 26: ...1 5 Accessories 1 35 Power I O cable 1 35 Power I O connector 1 36 ...
Page 64: ......
Page 78: ...2 14 2 Installation ...
Page 80: ......
Page 100: ...3 20 3 Wiring ...
Page 124: ...4 22 4 Operation ...
Page 126: ......
Page 132: ...5 6 5 Preventive Predictive Maintenance ...
Page 134: ......
Page 148: ...6 14 6 Parameters ...
Page 150: ......
Page 168: ...7 18 7 Troubleshooting ...
Page 170: ......
Page 208: ......
Page 212: ......
Page 214: ...10 2 10 Life ...
Page 216: ......
Page 219: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 220: ......
Page 225: ......