FRU Removal and Replacement
242
Figure 77: Redundant power supply removal and replacement
Replacing the Power Supply
To replace a redundant power supply:
1. Remove the replacement power supply from its protective antistatic bag.
2. Inspect the rear of the power supply for bent or broken connector pins that
may have been damaged during shipping. If any pins are damaged, obtain a
new power supply.
3. Insert the power supply into the chassis guide of the AC module, then push
the power supply toward the backplane to engage the connector pins.
4. Disconnect the ESD wrist strap from the director chassis and your wrist.
5. Inspect the power supply to ensure the green PWR OK LED is illuminated
and all amber LEDs are extinguished. If a problem is indicated, go to “
” on page 45 to isolate the problem.
1
Power supply
2
AC module
2
1