FRU Removal and Replacement
251
Figure 80: Fan module removal and replacement
Caution:
Do not remove a fan module unless the replacement module is
available. Operation of the director with only one fan module for an
extended period may cause one or more thermal sensors to post event codes.
6. Using the rear of the fan module as a handle, pull the module from the
director. Support the fan module with one hand when performing this step.
7. Place the fan module in an antistatic bag to provide ESD protection.
Replacing the Fan Module
To replace the fan module:
1. Remove the replacement fan module from its protective antistatic bag.
2. Inspect the PWA on the underside of the fan module for bent or broken
connector pins that may have been damaged during shipping. If any pins are
damaged, obtain a new fan module.
1
Fan module
1