Diagnostics
132
3. Choose the This port (n) only option (where n is the port number) and click
OK. The link incident clears.
4. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES
NO
↓
The problem is transient and the Fibre Channel link and director are
operational. Exit MAP.
34
Inspect the fiber optic jumper cable attached to the port and ensure the cable is not
bent and connectors are not damaged. If the cable is bent or connectors are
damaged:
1. Notify the customer the port will be blocked. Ensure the customer’s system
administrator quiesces Fibre Channel frame traffic through the port and sets
the attached device offline.
2. Block the port (“
3. Remove and replace the fiber optic jumper cable.
4. Unblock the port (“
Was a corrective action performed?
YES
NO
↓
35
Monitor port operation for approximately five minutes.
Did the link incident recur?
YES
NO
↓
The Fibre Channel link and director are operational. Exit MAP.
36
Clean fiber optic connectors on the jumper cable.
1. Notify the customer the port will be blocked. Ensure the customer’s system
administrator quiesces Fibre Channel frame traffic through the port and sets
the attached device offline.
2. Block the port (“
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...