Diagnostics
76
22
At the Hardware View, does a yellow triangle display at the alert panel and a
blinking red and yellow diamond (failed FRU indicator) display over a power
supply graphic?
NO
YES
↓
A redundant power supply failed. Go to
23
At the Hardware View, does a grey square display at the alert panel, a
No Link
status displays at the director Status table, and graphical FRUs are uninstalled?
YES
NO
↓
A green circle displays at the alert panel and the director is
operational. Exit MAP.
The grey square indicates the HAFM appliance cannot communicate with the
director because:
■
The director-to-HAFM appliance Ethernet link failed.
■
AC power distribution in the director failed, or AC power was disconnected.
■
Both of the director’s CTP cards failed.
Continue to the next step.
24
Ensure the director reporting the problem is connected to facility AC power and
the power switch (circuit breaker) at the rear of the director is set to the ON (up)
position. Inspect the director for indications of being powered on, such as:
■
At the front bezel, an illuminated power LED (green) or system error LED
(amber).
■
An illuminated green LED on the active CTP card.
■
At least one green PWR OK LED illuminated on a power supply.
■
Audio emanations and airflow from cooling fans.
Is the director powered on?
YES
NO
↓
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...