Diagnostics
64
c.
Return to the View panel (Port Properties tab).
Continue to the next step.
47
At the View panel, does the Operational State field display a
Segmented
message?
NO
YES
↓
Port segmentation is indicated. Go to
to obtain event codes. If
no event codes are found, go to “
Segmented Port Problem Determination
” on page 138. Exit MAP.
48
At the View panel, does the Operational State field display a message indicating
a port problem?
NO
YES
↓
Go to
to obtain event codes. If no event codes are found, go to
MAP 0600: UPM Card Failure and Link Incident Analysis
page 115. Exit MAP.
49
Repeat
through
for each remaining Fibre Channel port for which a
problem is suspected.
Is a problem indicated for any of the ports?
NO
YES
↓
Go to
to obtain event codes. If no event codes are found, go to
MAP 0600: UPM Card Failure and Link Incident Analysis
page 115. Exit MAP.
50
Inspect power supply operational states.
1. At the View panel, click the FRU Properties tab. The View FRU Properties
panel displays, as shown in
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...