FRU Removal and Replacement
244
RRP: AC Module
Use the following procedures to remove or replace the AC module. A list of tools
required is provided.
Tools Required
The following tools are required to perform these procedures.
■
Standard cross-tip (Phillips) screwdriver.
■
ESD grounding cable and wrist strap.
Removing the AC Module
To remove the AC module:
1. If the director is installed in a stand-alone configuration, go to
step 2
. If the
director is rack-mounted, unlock and open the cabinet front door as directed
by the HP authorized service provider.
2. Follow ESD procedures by attaching a wrist strap to the director chassis and
your wrist, as shown in
.
WARNING:
Ensure the power cord is disconnected from the defective AC
module.
Caution:
To avoid causing machine errors or damage while working on the
director, follow ESD procedures by connecting a grounding cable to the
director chassis and wearing an ESD wrist strap.
3. Identify the defective AC module from the extinguished green PWR OK
LED on the supply or failure information at the Hardware View.
4. Remove the power supply from the defective AC module (“
5. Remove the two panhead Phillips screws that secure the AC module to the
director chassis, as shown in
6. Pull the power supply (
1
) from the director AC module (
2
), as shown in
. Support the AC module with one hand.
7. Place the AC module in an anti-static bag to provide ESD protection.
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...