Event Code Tables
384
Event Code: 802
Message:
UPM card shutdown due to thermal violation.
Severity:
Major.
Explanation:
An UPM card failed and was powered off because of excessive heat. This event
follows an indication that the hot temperature threshold was reached or exceeded
(event code 801).
Action:
Replace the failed UPM card with a functional UPM card of the same type. Perform
the data collection procedure and return the backup CD and faulty card to HP
support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Event Code: 805
Message:
High temperature warning (SBAR assembly thermal sensor).
Severity:
Major.
Explanation:
The thermal sensor associated with an SBAR assembly indicates the warm
temperature threshold was reached or exceeded.
Action:
Replace the indicated SBAR assembly with a functional assembly. Perform the data
collection procedure and return the backup CD and faulty assembly to HP support
personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...