Repair Information
198
— As the network connection drops, the Director 2/140 Status table turns
yellow, the Status field displays
No Link
, and the State field displays
Link Timeout
.
— The status bar at the bottom of the window displays a grey square,
indicating director status is unknown.
— Illustrated FRUs disappear, and appear again as the connection is
re-established.
IPL the Director from the HAFM Appliance
To IPL the director from the HAFM appliance, perform the following:
1. Open the HAFM application. The View All - HAFM 8 main window displays.
2. Double-click the icon representing the director to be IPLed. The Hardware
View for the selected director displays.
3. Choose Maintenance > IPL. The Information dialog box displays, as shown
in
Figure 51: Information dialog box
4. Click Yes to IPL the director. During the IPL, the director-to-HAFM
appliance Ethernet link drops momentarily and the following occur at the
Element Manager:
— As the network connection drops, the Director 2/140 Status table turns
yellow, the Status field displays
No Link
, and the State field displays a
reason message.
— In the HAFM Physical Map, the director icon displays a grey square,
indicating director status is unknown.
— Illustrated FRUs in the Hardware View disappear, and display again as
the connection is reestablished.
Reset the Director from the CTP Front Panel
To reset the director from the CTP front panel, perform the following:
1. Press and hold the RESET button for approximately three seconds.
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...