Diagnostics
140
Does the Operational State field indicate Segmented E_Port?
YES
NO
↓
Analysis for a UPM card failure or other link incident is not described
MAP 0600: UPM Card Failure and Link Incident
” on page 115. Exit MAP.
6
Inspect the Segmentation Reason field at the Port Properties dialog box.
lists port segmentation reasons and associated steps that describe fault
isolation procedures.
7
A minor error occurred that caused fabric services databases to be reinitialized to
an empty state. As a result, a disruptive fabric logout and login occurred for all
attached devices. The following list explains the errors.
■
Event code 010—Following a CTP card reset, the login server attempted to
acquire a fabric server database copy from the other CTP card and failed.
■
Event code 011—Following a CTP card failover, the login server database
failed cyclic redundancy check (CRC) validation.
■
Event code 020—Following a CTP card reset, the name server attempted to
acquire a fabric server database copy from the other CTP card and failed.
■
Event code 021—Following CTP card failover, the name server database
failed CRC validation.
Table 17: MAP 0700: Segmentation Reasons and Actions
Segmentation Reason
Action
Incompatible operating parameters.
Go to
Duplicate domain IDs.
Go to
Incompatible zoning configurations.
Go to
Build fabric protocol error.
Go to
No principal switch.
Go to
No response from attached switch.
Go to
ELP retransmission failure timeout.
Go to
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...