Diagnostics
143
13
As indicated by an event code 072, a director E_Port is connected to an
unsupported switch or fabric element.
Advise the customer of the problem and disconnect the interswitch link to the
unsupported switch. Exit MAP.
14
A director E_Port segmented because the error detect time out value (E_D_TOV)
or resource allocation time-out value (R_A_TOV) is incompatible with the
attached fabric element.
1. Contact HP customer support or engineering personnel to determine the
recommended E_D_TOV and R_A_TOV values for both directors.
2. Notify the customer that both directors will set offline. Ensure the system
administrator quiesces Fibre Channel frame traffic through the directors and
sets attached devices offline.
3. Set both directors offline (“
4. At the Hardware View for the first director reporting the problem, choose
Configure > Operating Parameters > Fabric Parameters. The Configure
Fabric Parameters dialog box displays, as shown in
.
5. Type the recommended E_D_TOV and R_A_TOV values, then click
Activate.
6. Repeat
and
at the Hardware View for the director attached to
the segmented E_Port (second director). Use the same E_D_TOV and
R_A_TOV values.
Table 18: MAP 0700: Byte 4, Segmentation Reasons
Byte 4
Segmentation Reason
Action
01
Incompatible operating parameters.
Go to
02
Duplicate domain IDs.
Go to
03
Incompatible zoning configurations.
Go to
04
Build fabric protocol error.
Go to
05
No principal switch.
Go to
06
No response from attached switch.
Go to
07
ELP retransmission failure timeout.
Go to
Summary of Contents for StorageWorks 2/140 - Director Switch
Page 18: ...About this Guide 18 Director 2 140 Service Manual ...
Page 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Page 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Page 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Page 318: ...Information and Error Messages 318 Error Messages ...
Page 388: ...Event Code Tables 388 Director 2 140 Service Manual ...